Olympus

Beckman Olympus AU 2700 Chemistry Analyzer
Model : AU 2700
Beckman Olympus AU 2700 Chemistry Analyzer Highlights
Fast and reliable turnaround times
· Up to 1600 photometric tests per hour and up to 2133 tests per hour with electrolytes
· Immediate STAT interrupt with HCFA basic metabolic eight test panel results available within five minutes
Walk away design saves operator time
· 300-sample rack loading for peak workloads
· 22-sample carousel for STAT
· Direct tube sampling for 3.0, 5.0, 7.0, 10.0 mL primary tubes and pediatric cups
· Mixed bar code capability
· Automated reflex and repeat testing
· Automated pre-dilution for urine and other specimens
· Easy connectivity for automation
Automated reagent handling
· Reagents are liquid and ready-to-use
· Barcoded cartridges provides on-board management (random placement, on-board stability and calibration tracking)
· All 48 R1 and 48 R2 reagent positions are open for third-party reagent use
· Auto-calibration and auto-quality control
· Automatic changeover from empty to fresh bottle
· Multiple sized reagent cartridges hold from 100 to 6000+ tests to meet the needs of any size laboratory
· Minimal reaction volume of 120 µL reduces reagent consumption
· Reagent inventory tracking function predicts daily workloads
Efficient review of results
· Choice of QC trending: Westgard multi-rule procedure, Twin plots, Levey-Jennings daily and day-to-day plots
· Search function to retrieve data by individual sample and type of test (up to 60,000 patient files)
· User-definable flags for abnormal results
Precision engineering for reliability and accuracy
· Liquid level capacity detection to ensure accurate pipetting for reagents and specimens
· Clot detection and crash prevention for probes
· Exclusive spot photometric technology for precision optics
User-friendly Windows NT® software simplifies training and operation
· Drop-down menus, icons, color-keyed graphics
· User menu to customize operation
· Operator’s guide with links, search, and bookmarks
· Software capabilities support CLIA, NCCLS, and CAP compliance
· Computer-displayed maintenance videos
· Modem-linked technical support
Maintenance: Automated for minimum operator time
· Programmable start-up
· Automated washes and checks
· Dry-bath technology means no water bath maintenance
· Minimum disposables:
· Permanent glass cuvettes
· ISE electrodes are warranted for six months
No sample or reagent tips to replace
Weight: 1,540 Lbs
Dimensions: 79 (W) x 45 (D) x 50 (H) inches

Beckman Olympus AU 400/400e Chemistry Analyzer
Model : AU 400/400e
Analytical system |
Fully automated, for routine, STAT, urine and homogeneous Immuno Assays |
Analytical methods |
Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE |
Simultaneously processed analytes |
Up to 38 photometric tests + 3 ISE |
Throughput |
400 photometric tests / hour; maximum of 800 with ISE |
Sample feeder |
Racks with 10 samples each (bar-codes on primary tubes and on racks); capacity of 80 samples; continuous loading |
Sample tubes |
In primary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm |
STAT samples |
Up to 22 positions for STAT samples, bar-coded primary tubes |
Sample volume |
2 – 50 µl in 1 µl steps (1– 50 µl for repeats) |
Reagent supply |
Refrigerated (4 °C – 12 °C); 76 positions for R1/ R2 |
Reagent volume |
1. reagent: 25 – 300 µl; 2. reagent: 25 – 300 µl; (in 1 µl steps) |
Total reaction volume |
150– 550 µl |
Reaction cuvette |
Quartz cuvettes |
Reaction time |
Up to 8 minutes, 40 seconds |
Reaction temperature |
37 °C |
Mixing method |
With rotating paddles after dispensing sample and reagent |
Photometry system |
Direct assay through the reaction cuvette (0 – 2.5 OD) mono-, bichromatic measurements possible |
Wave length |
13 different wave lengths between 340 – 800 nm |
Cuvette cleaning |
Comprehensive cleaning with detergents |
Calibration |
Linear and non linear (linear interpolation), refrigerated calibrator positions |
Data processing |
Calculated parameters, blank value correction and correlation. Definition of normal value range, measuring range, pathological values and repeats. Quality controls, printout of abnormal values, pending sample work list and repeat run sample list |
Test requisition |
Individual and profile test requisition via on-line, mouse, function keys or optional touch screen |
Safety |
Clot detection and crash prevention for sample and reagent dispenser |
On-line |
Full uni- and bidirectional communication possible |
Software |
Windows-NT® |
Weight: 924 Lbs.
Dimensions: 56 (W) x 30 (D) x 48 (H) inches

Beckman Olympus AU 480 Chemistry Analyzer
Model : AU 480
Beckman Olympus AU 480 Chemistry Analyzer Highlights
The system has twin sampling capability via rack loading or a cooled STAT turntable module. The sample rack feeder can hold up to 80 primary and secondary tubes in parallel. Different tube sizes may be mixed within the racks and can be loaded continuously. The STAT module provides quick emergency testing, on-board calibrator and QC storage for system access during auto calibration and auto QC.
New state of the art sample and reagent volumes have been reached. Sample volumes as low as 1 µl, ideal for pediatric testing and reaction volumes down to as low as 90 µl guarantees cost efficiency. Computer controlled sample- and reagent dispensing based on CAN* technology in combination with clot detection and crash prevention are additional safety features which result in unique system reliability. The system security is further improved by context sensitive help screens and videos.
The AU480 Chemistry System has a new intuitive Graphic user interface, standardized to the AU680 minimizing any training requirements. A new ergonomically designed swing arm with a user friendly touch screen monitor is now available. User definable software options such as auto rerun via rack handler / STAT wheel and true reflex testing expand the convenience for the user.
Automated low level maintenance requiring minimum hands-on time by the operator. TheAU480 Chemistry System uses dry bath technology therefore requiring no water bath maintenance. Low consumable replacement for example permanent cuvettes, long life electrodes (guaranteed for 6 months), robust sample and reagent probes.
The AU480 Chemistry System combines versatile advanced functions that facilitate high quality testing, improve turnaround time and cut operating costs. To minimize training requirements and assure safe handling by inexperienced staff, we emphasized ‘Easy to Use’ in developing the analyzer.
TheAU480 Chemistry System will continue to live up to the Beckman Coulter reputation of being the analyzer that is “reliable and precise”.
Improved convenience
· New and intuitive graphical user interface
· Embedded maintenance videos
· Universal applications
· Plug and play calibration via 2-D barcode
Efficiency
· Reagent reduction
· Low consumable usage
· Microsampling ideal for pediatrics
Continuous loading sample feeder
· Positive sample identification
· Beckman Coulter flexible racks to handle all commonly used tube sizes in parallel
· Barcoded racks to define different sample materials
· 80 samples on board at any time
· Automatic repeat and reflex capability
Flexible STAT rotor
· Dedicated STAT rotor with 22 positions and integrated barcode reader
· Full STAT capabilities during routine operation
· Refrigerated area for calibrators and controls
· Combined routine and emergency work area
Large reagent compartment
· 76 refrigerated reagent compartments
· Ready to use liquid stable reagents
· Automatic bottle switch capabilities
· Advanced calibration
· Liquid detection and remaining test number calculation
Cuvette wheel with low maintenance
· Non disposable quartz cuvettes
· Software driven carry over elimination
· Dry incubation bath
· Environmental friendly
Best in class ISE
· High quality ISE for Na, K and Cl
· 6 months shelf life
· 18 months shelf life for reference electrodes
· 600 tests/hour (if ISE mode only)
· Same technology across the whole range of analyzers
Weight: 926 Lbs
Dimensions: Width: 57″ Height: 47″ Depth: 30″

Beckman Olympus AU 5431 Chemistry Analyzer
Model : AU 5431
Beckman Olympus AU 5431 Chemistry Analyzer Highlights
Modular Configuration
· Configurable as the two module AU5421 or the three module AU5431
· Choice of single or dual flowcell ISE module
· Analyzer modules are user configurable to match user needs for test channels and throughput
· Optional auto-repeat and refrigerated QC modules available
Fast and reliable turnaround times
· True random access
· Precision reagent dispensing without priming requirements
· Throughput of up to 6,600 tests per hour
· AU5421 – (2 analyzer modules)
· 3,200 photometric tests/hour
· 4,100 tests/hour with single ISE
· 5,000 tests/hour with dual ISE
AU5431 – (3 analyzer modules)
· 4,800 photometric tests/hour
· 5,700 tests/hour with single ISE
· 6,600 tests/hour with dual ISE
Precision Sampling
· Liquid level capacity detection for accurate sampling : 2-6 µL for most tests
· Clot detection
· Probe crash prevention
Peak workloads with 300 sample load for extended walk-away time
· Continuous feed rack loader
· Easy connectivity for automation
· “Flex” racks accommodate mix of tube sizes
Flexible sample handling
· Mixed barcode feature
· Variety of tube sizes
· Automated repeat testing (with optional unit) for abnormal sample results eliminates hands-on sample reprocessing
· Pre-dilution for urines
· Antigen check for prozone (e.g., myelomas)
Automated reagent handling
· Reagents are liquid and ready-to-use
· Reagent pipetting system eliminates priming
· Multiple sized reagent cartridges hold from 100 to 6000+ tests to meet the needs of any size laboratory
· Barcoded cartridges provide on-board management (random placement, on-board stability and calibration tracking)
· Automatic changeover from empty to fresh bottle
· Calibrate up to 5 sets of reagent cartridges at one time
· All 48 reagent positions per analyzer module are open for third-party reagent use
· Minimal reaction volume of 120 µL reduces reagent consumption
· Reagent inventory tracking function predicts daily workloads
Software: Easy to use and train
· Easy to navigate software with drop-down menus, icons, and color-keyed graphics
· User menu to customize operation
· On-screen review of QC, system status, and calibration status
· Intelligent online guidance:
· Operator’s guide with links, searches, and bookmarks
· Context-specific HELP
· Online, computer-displayed maintenance videos
· Modem-linked technical support
CLIA compliance:
· Operator log-in
· Commentary for editing of QC, calibration, or patient results
· Multi-level user definable password protection for software menus
· Maintenance log for compliance tracking
· Tracking of reagent consumption and consumables
Automated maintenance for minimum operator time
· Programmable start-up
· Automated washes and checks
· Dry-bath technology means no water bath maintenance
· Minimum disposables:
· Permanent glass cuvettes
· ISE electrodes are warranted for six months
· No sample or reagent tips to replace
· Without ISE
· Weight: 3,696 Lbs
· Dimensions: 182 (W) x 45 (D) x 50 (H) inches
· With ISE
· Weight: 3,916 Lbs
· Dimensions: 200 (W) x 45 (D) x 50 (H) inches

Beckman Olympus AU 640/640e Chemistry Analyzer
Model : AU 640/640e
Beckman Olympus AU 640/640e Chemistry Analyzer Highlights
Analytical system |
Fully automated, for routine, STAT, urine and homogeneous immunoassays |
Analytical methods |
Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE |
Simultaneously processed analytes |
48 photometric tests, 51 with ISE |
Throughput |
800 photometric tests/hour; maximum of 1,200 with ISE |
Sample feeder |
Racks with 10 samples each (bar codes on primary tubes and on racks); capacity of 150 samples; continuous loading |
Sample tubes |
In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm |
STAT samples |
Up to 22 positions for STAT samples, bar coded primary tubes |
Sample volume |
2 – 50 µl in 1 µl steps (1 – 50 µl for repeats) |
Reagent supply |
48 positions for R1 and R2; refrigerated (4 °C – 12 °C) |
Reagent volume |
1. reagent: 25 – 300 µl; 2. reagent: 25 – 300 µl; (in 1 µl steps) |
Total reaction volume |
150 – 550 µl |
Reaction cuvette |
Quartz cuvettes |
Reaction time |
Up to 8 minutes, 40 seconds |
Reaction temperature |
37 °C |
Mixing method |
With rotating paddles after dispensing sample and reagent |
Photometry system |
Direct assay through the reaction cuvette (0 – 2.5 OD) mono, bichromatic measurements possible |
Wavelength |
13 different wavelengths between 340 – 800 nm |
Cuvette cleaning |
Comprehensive cleaning with detergents |
Calibration |
Auto calibration, cooled calibrator positions |
Quality control |
Auto QC, cooled QC positions |
Test requisition |
Individual and profile test requisition via on line, mouse, functions keys or touch screen |
Safety |
Clot detection and crash prevention for sample and reagent dispenser |
On-line |
Full uni- and bidirectional communication possible |
Software |
Windows-NT |
Dimensions (W x H x D) mm |
ANL 1,850 x 1,210 x 800; DPR 700 x 1,430 x 700 |
Weight: 1,166 Lbs
Dimensions: 73 (W) x 48 (H) x 32 (D) inches

Beckman Olympus AU 680 Chemistry Analyzer
Walk away design saves operator time

Beckman Olympus PK7300 Chemistry Analyzer
Model : PK7300
Beckman Olympus PK7300 Chemistry Analyzer Highlights
PK7300 Offers:
· 300 sample per hour throughput
· Full online system status updates
· Data transfer capabilities
· Liquid level sensors for reagent and diluents volume detection
· Aspiration and dispense monitoring intelligence
· Self monitoring of critical instrument processes with alarms including result invalidation for abnormal conditions