GE OEC ?9900
? 60kHz high frequency
? 15kW power
? Up to 120kVp
? Up to 75mA for radiographic film exposure
? Continuous high level fluoro (HLF) up to 20mA
? Digital spot up to 75mA
? Pulsed HLF up to 40mA
? Full power from standard wall outlet
? Patented battery buffered design
? X-Ray Tube
? X-Ray Tube
? Rotating anode X-ray tube
? 0.3mm and 0.6mm focal spots
? Anode heat capacity: 300,000 HU
? Anode cooling rate: 85,000 HU/min.
? Housing heat capacity: 1,600,000 HU
? Housing cooling: -9? II = 22,500 HU/min, 12? II = 22,500 HU/min
? Digital Image Orientation
? Digitally adjusts image display for live and last image hold
? Automatic image update preserves image orientation settings applied during live and last image hold subsequent images
? Image rotation
? Image reversal (side-to-side)
? Image invert (top-to-bottom)
? On-screen orientation indicator
? Fully digital with precise 1-degree rotation increments
? PreView? Collimator
? On-screen collimator position indication
? PreView iris collimator
? PreView Tungsten rotatable double leaf collimator
? Adjusts collimators without X-ray exposure
? Fluoro Mode
? kVp range: 40 -120
? mA range: 0.2 ? 10 normal mode 0.2 ? 20 HLF (high level fluoro)
? Auto and manual fluoro modes
? Pulsed Fluoro Mode
? kVp range: 40 ? 120
? mA range: 0.2 ? 10 normal mode, 0.2-40 HLF
? Pulse rate: 8 pps
? Pulse width: 25 ms
? Auto and manual pulsed fluoroscopy modes
? Reduces x-ray dose to patient and operator
? Digital Spot Mode
? kVp range: 40 ? 120
? mA range: Up to 75
? Automatic exposure termination and automatic image save
? 9? Image Intensifier
? Tri-mode 9?/6?/4.5? (23cm/15cm/11cm) image intensifier
? Minimum central resolution (at the monitor):
? 9? (23cm): 2.2 lp/mm
? 6? (15cm): 3.0 lp/mm
? 4.5? (11cm): 3.5 lp/mm
? DQE: 65% (typical)
? Removable Grid
? 12? Image Intensifier
? Tri-mode 12?/9?/6? (31cm/23cm/15cm) image intensifier
? Minimum central resolution (at the monitor):
? 12? (31cm): 1.6 lp/mm
? 9? (23cm): 2.2 lp/mm
? 6? (15cm): 2.6 lp/mm
? DQE: 65% (typical)
? Removable Grid
Precision imaging with Dynamic Range Management (DRM) enhances features of interest while attenuating background noise
? Preset Imaging Profiles
? 9800
? General
? Orthopedic
? Spine
? Cardiac
? Vascular
? Bolus Chase
? AutoTrak Automatic Brightness Stabilization (ABS)
? Automatically seeks the subject anatomy anywhere within the imaging field
? Selects the optimum imaging technique by varying mA, kVp, and gain
? Automatically adjusts to anatomical size and location
? Provides uniform image quality throughout the entire image
? Image I.Q.
? Smart Window
? Dynamically senses the collimator position and automatically adjusts brightness and contrast to produce high image quality.
? Smart Metal
? Allows user to adjust automatic brightness and contrast sensitivity levels to metal
? Provides optimum image quality even when metal is introduced to the field
? Tungsten Collimator
? Denser collimator limits X-ray exposure area
? Reduces scatter radiation
? Improves image detail
? Video Monitor
? 27 in (69 cm) LCD TFT color display
? Anti-glare
? Monitor mounted on an articulating arm
? 45 in (114 cm) horizontal travel
? 17 in (43.2 cm) vertical travel
? 27 in (68.8 cm) forward travel
? 5? up/5? down tilt
? Display viewable from all four sides of workstation
? Horizontal and vertical viewing angle 170?
? 450 cd/m2 maximum brightness
? Touch screen system control
? 2560 x 1440 high resolution display
? Integrated PIP window to display color DVI-D input